Please note. Standard numbers and rules change. This page is a learning guide. Before manufacture, import, sale or tender, buy the current standard from BIS and read the latest government notification.
Standards help makers and buyers speak the same language. They define how a motor is rated, tested, labelled and protected. Knowing the main ones helps you answer customer questions, pass audits and win tenders.
Main standards for motors in India
| Standard | What it covers |
|---|---|
| IS 12615 | Line operated three phase AC motors: efficiency classes and performance (IE code) |
| IS 325 | Three phase induction motors: general requirements |
| IS 996 | Single phase small AC and universal motors |
| IS/IEC 60034-1 | Rating and performance of rotating electrical machines (general) |
| IS/IEC 60034-2-1 | Methods to determine losses and efficiency by testing |
| IS/IEC 60034-5 | Degrees of protection (IP code) |
| IS/IEC 60034-6 | Cooling methods (IC code) |
| IS/IEC 60034-7 | Mounting arrangements (IM code) |
| IS/IEC 60034-9 | Noise limits |
| IS/IEC 60034-14 | Mechanical vibration |
| IS/IEC 60034-30-1 | Efficiency classes IE1 to IE4 (international) |
BIS certification and Quality Control Orders
In India, the Bureau of Indian Standards (BIS) runs product certification under the ISI mark. For some products the Government issues a Quality Control Order (QCO), which makes it illegal to manufacture, import or sell the product without the BIS mark. Line operated three phase AC motors under IS 12615 are under a QCO. The motor range, dates and exemptions can change, so check the latest notification before you plan production or import.
Good to know: a factory with a good quality system (such as ISO 9001) finds BIS licensing much easier, because testing, calibration and records are already in place.
Energy labelling by BEE
The Bureau of Energy Efficiency (BEE) has a Standards and Labelling programme for several products. Induction motors are in the programme. Check the BEE website for the present scope, the star levels and whether labelling is voluntary or mandatory for your product.
IE efficiency classes in one table
| Class | Name | Meaning |
|---|---|---|
| IE1 | Standard efficiency | Basic level, becoming rare in new supply |
| IE2 | High efficiency | Better than IE1; about 1 to 3 percentage points higher in typical sizes |
| IE3 | Premium efficiency | Present target for most industrial motors in India |
| IE4 | Super premium | Often needs special design (copper rotor, PM or reluctance) and a VFD |
Details and rupee savings: IE1 IE2 IE3 IE4 explained.
Voltage, frequency and temperature: what the standard assumes
- Voltage variation of plus or minus 5 percent and frequency variation of plus or minus 2 percent (the standard "zone A") are allowed for full rated performance.
- Standard ambient temperature is up to 40 C and altitude up to 1000 m. Beyond this, derate the motor.
- Insulation classes: B = 130 C, F = 155 C, H = 180 C. Temperature rise limits depend on the class and the method of measurement.
Routine tests before dispatch
Typical routine tests are winding resistance, insulation resistance, high voltage (dielectric) test, no-load test, and checks of rotation, vibration and noise. Type tests such as the heat run, locked rotor and efficiency (load) tests are done on sample motors. For the full test plan follow the standard and your customer order.
Related: how motors are made · motor selection guide.
Common questions
Which Indian standard covers three phase induction motors?
IS 325 covers three phase induction motors in general, and IS 12615 covers line operated three phase AC motors with efficiency classes (IE1, IE2, IE3 and so on). IS 12615 is aligned with IEC 60034-30-1.
Is BIS certification mandatory for electric motors in India?
For line operated three phase AC motors covered by IS 12615, BIS certification (ISI mark) is required under a Quality Control Order. The scope, power range and dates can change, so check the latest BIS and DPIIT notification before you manufacture, import or sell.
What is the BEE star label for motors?
BEE (Bureau of Energy Efficiency) runs an energy labelling programme for some products including induction motors. Check the current BEE notification for the scope and whether it is voluntary or mandatory for your product.
What does IE3 mean?
IE3 is the 'Premium efficiency' class in IEC 60034-30-1. IE1 is standard, IE2 is high, IE3 is premium and IE4 is super premium efficiency. See our IE class guide for a rupee example.
Which standard gives the IP code and cooling code?
IP (protection) is covered by IS/IEC 60034-5, and the cooling method code (such as IC411) by IS/IEC 60034-6. Mounting codes (such as IM B3) are in IS/IEC 60034-7.
Information here is for learning. For design, purchase or legal decisions, check the latest BIS, BEE and IEC standards and your motor maker's data sheet.
Have a question about motors? Ask the community.
Ask questions, share your shop-floor learning, and meet motor makers from all over India.