This page collects the calculations that motor engineers, students and buyers use every day. Each formula is shown in simple form with a worked example, so you can check your own numbers. These are first-pass estimates. For a final design, always verify with simulation, testing and the standard (IS / IEC) that applies to your product.
1. Speed, number of poles and synchronous speed
Synchronous speed (rpm) = 120 x f / P
f = supply frequency in Hz, P = number of poles.
| Poles | Synchronous speed at 50 Hz | Typical full load speed |
|---|---|---|
| 2 | 3000 rpm | 2880 to 2950 rpm |
| 4 | 1500 rpm | 1400 to 1470 rpm |
| 6 | 1000 rpm | 940 to 980 rpm |
| 8 | 750 rpm | 700 to 735 rpm |
Slip = (Ns - N) / Ns. Example: a 4 pole motor running at 1440 rpm has slip = (1500 - 1440) / 1500 = 0.04, or 4 percent.
With a VFD, you change f, so speed changes. Example: a 4 pole motor at 30 Hz has synchronous speed 120 x 30 / 4 = 900 rpm.
2. Motor torque formula and how to calculate power from torque and rpm
Torque (Nm) = 9550 x Power (kW) / Speed (rpm)
Power (kW) = Torque (Nm) x Speed (rpm) / 9550
The number 9550 comes from 60 x 1000 / (2 x pi). It is simply unit conversion.
Example A (torque from power): 7.5 kW motor at 1440 rpm. Torque = 9550 x 7.5 / 1440 = 49.7 Nm.
Example B (power from torque): A load needs 50 Nm at 1000 rpm. Power = 50 x 1000 / 9550 = 5.24 kW. Choose the next standard size above this, and add margin (see sizing below).
3. Full load current and starting current
Full load current (3 phase) I = P x 1000 / (1.732 x V x efficiency x power factor)
P = shaft output in kW, V = line voltage in volts.
Example: 7.5 kW, 415 V, efficiency 0.90, power factor 0.85.
1.732 x 415 = 718.8; x 0.90 = 646.9; x 0.85 = 549.9.
I = 7500 / 549.9 = 13.6 A.
Motor starting current. In direct on line (DOL) starting, an induction motor draws about 6 to 8 times full load current. For the motor above: 13.6 x 7 = about 95 A. With a star-delta starter, the starting current is about one third of DOL, so about 32 A. A soft starter or VFD can limit it further. Check the data sheet for the exact ratio (locked rotor current).
4. kW to HP conversion for motors
1 HP = 0.746 kW and 1 kW = 1.34 HP
| kW | 0.37 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 |
|---|---|---|---|---|---|---|---|---|---|
| HP (approx) | 0.5 | 1 | 2 | 3 | 5 | 7.5 | 10 | 15 | 20 |
5. Motor sizing calculation (simple method)
- Find the load. Force, speed, or torque and rpm at the shaft.
- Find power at the load. Power = Force (N) x Speed (m/s).
- Add losses. Divide by the efficiency of gearbox, belt or coupling.
- Add a margin. Many designers keep 15 to 25 percent for starting and variations.
- Pick the next standard size and check the starting torque and the duty cycle.
Example (conveyor): Pull force 500 N, belt speed 1.2 m/s, gearbox efficiency 0.85.
Load power = 500 x 1.2 = 600 W. With gearbox loss: 600 / 0.85 = 706 W. With 20 percent margin: 847 W. The next standard size is 1.1 kW (0.75 kW would be too small).
Also check: ambient temperature above 40 C or altitude above 1000 m needs derating. Frequent starts need a higher thermal rating. Avoid heavy oversizing: a lightly loaded motor has poor efficiency and power factor.
6. Induction motor design: stator winding and air gap
Designers start from the output equation: kVA output depends on D squared x L x speed, where D is the stator bore diameter and L is the core length. From the output equation you get the main dimensions (D and L). Then you choose the winding.
EMF per phase: E = 4.44 x f x Flux per pole x Turns per phase x Winding factor
Example (turns per phase): Star connected, 415 V line gives 240 V per phase. f = 50 Hz, flux per pole = 0.0095 Wb, winding factor 0.955.
Turns = 240 / (4.44 x 50 x 0.0095 x 0.955) = 240 / 2.014 = about 119 turns per phase.
Conductor size: Area = Current / Current density. For totally enclosed motors, a common starting current density is 3 to 5 A per mm squared. At 13.6 A and 4 A/mm2, the area is about 3.4 mm2 (use parallel strands of thinner wire to fill the slot well).
Air gap in induction motors. A small air gap gives a low magnetising current and a better power factor, but it makes manufacturing harder (rotor rubbing, bearing play). A common rule of thumb is air gap (mm) = 0.2 + 2 x square root of (D x L), with D and L in metres. Example: D = 0.2 m, L = 0.15 m gives 0.2 + 2 x 0.173 = about 0.55 mm. Small motors use about 0.25 to 0.5 mm; large motors use more.
7. How to design a BLDC motor: Kv, back EMF constant and torque constant
Start with the requirement: rated torque, speed, supply voltage (for example 48 V) and the maximum current from the controller. Then fix the size from the torque needed per volume, choose the slot and pole combination, magnet grade and the winding.
Kv (rpm per volt) = 9.55 / Ke, and Kt (Nm per A) = Ke in SI units (Ke is the back EMF constant in volt-seconds per radian).
Example: Kv = 100 rpm/V. Then Ke = 9.55 / 100 = 0.0955 V.s/rad, and Kt = 0.0955 Nm/A.
No-load speed at 48 V = 100 x 48 = 4800 rpm.
Torque at 20 A = 0.0955 x 20 = 1.91 Nm.
Tips: more turns means a lower Kv (slower, more torque per amp, less current). Fewer turns means a higher Kv. The designer tunes the turns so that the motor reaches the required speed at the available voltage while the current stays within the controller and thermal limits. Ke and Kt here are line-to-line values for a standard 3 phase star motor.
8. Slot and pole combinations for BLDC and PMSM motors
The number of slots (S) and poles (2p) decides winding factor, cogging, noise and cost. Concentrated fractional-slot windings (one coil around one tooth) are popular because they are short, cheap to wind and efficient.
| Slots / poles | Winding factor (approx.) | Cogging periods per turn (LCM) | Comment |
|---|---|---|---|
| 9 / 6 | 0.866 | 18 | Simple, but unbalanced radial force |
| 9 / 8 or 9 / 10 | 0.945 | 72 / 90 | Good torque density, low cogging |
| 12 / 8 | 0.866 | 24 | Very common in small BLDC |
| 12 / 10 or 12 / 14 | 0.933 | 60 / 84 | Very popular in EV and robotics |
Rule of thumb: a higher LCM (least common multiple) of slots and poles gives lower cogging torque. Slots per pole per phase q = S / (2p x phases). If q is a fraction, it is a fractional-slot winding.
9. Cogging torque and torque ripple in BLDC motors
Cogging torque is the "notchy" torque you feel when turning an unpowered permanent magnet motor by hand. It comes from the magnets trying to line up with the slot teeth. Torque ripple is the variation of torque while the motor runs under current. It causes noise, vibration and speed fluctuation.
| Method | How it helps |
|---|---|
| Good slot / pole combination | Raises the LCM, so cogging is smaller from the start |
| Skewing (stator or magnet) | Cancels cogging harmonics; costs a little torque |
| Optimise magnet pole arc and shape | Smoothens the air-gap flux |
| Smaller slot opening or auxiliary notches | Reduces slot effect |
| Sinusoidal drive / harmonic current injection | Reduces ripple from current waveform (controller side) |
Simulation with finite element software is the best way to compare options. See our students and researchers page for tools and free software.
Related: types of electric motors, motor troubleshooting guide, glossary.
Common questions
What is the formula for motor torque?
Torque (Nm) = 9550 x Power (kW) / Speed (rpm). Also, Torque = Power (W) / angular speed (rad/s), where angular speed = 2 x pi x rpm / 60. A 7.5 kW motor at 1440 rpm gives about 49.7 Nm.
How do I find the speed of an induction motor from the number of poles?
Synchronous speed in rpm = 120 x frequency / number of poles. At 50 Hz: 2 poles = 3000 rpm, 4 poles = 1500 rpm, 6 poles = 1000 rpm, 8 poles = 750 rpm. The real shaft speed is a little lower because of slip.
How do I calculate full load current of a three phase motor?
I = P x 1000 / (1.732 x V x efficiency x power factor), where P is the output in kW and V is the line voltage. For 7.5 kW, 415 V, efficiency 0.90 and power factor 0.85 the current is about 13.6 A.
What is the Kv rating of a BLDC motor?
Kv is the no-load speed in rpm that you get for every 1 volt applied. A 100 Kv motor on 48 V runs near 4800 rpm with no load. A higher Kv means higher speed and lower torque per amp.
How many kW is 1 HP?
1 HP (mechanical) is 0.746 kW. Motor nameplates in India often use kW, but shops still say HP. So 7.5 kW is about 10 HP.
How do I reduce cogging torque in a BLDC motor?
Choose a slot and pole combination with a high least common multiple, skew the stator or the magnets, optimise the magnet pole arc, use a smaller slot opening, or shape the magnet edges. Most designs use a mix of these.
Information here is for learning. For design, purchase or legal decisions, check the latest BIS, BEE and IEC standards and your motor maker's data sheet.