A borewell submersible motor is an induction motor squeezed into a long, thin tube that runs under water for years. Small diameter, water cooling, and no easy access are what make its design and winding different from a normal surface motor.
1. Introduction
India is one of the biggest users of submersible pumpsets – for farms, apartments and drinking water schemes. Most are 1-phase (up to about 1.5–2 HP) or 3-phase motors sized to fit 100 mm (V4), 150 mm (V6) and 200 mm (V8) borewells. When a motor burns, it is usually rewound locally, so good winding practice directly decides how long the pump will last.
2. How it is built
- Long, thin stator: the bore diameter is limited by the well, so power comes from a long stack length. This is why efficiency and power factor are lower than a surface motor of the same HP.
- Squirrel-cage rotor running in water-lubricated bearings, with a thrust bearing at the bottom to carry the pump's down-thrust.
- Cooling comes from the water flowing past the motor shell. The motor must sit above the inlet or have a flow sleeve so water moves over it.
- Sealing: mechanical seal or lip seal on the shaft, sand guard, and a diaphragm that balances internal pressure.
- Cable joint: the flat cable is joined to the motor leads with a sealed joint. A poor joint is the number one cause of water entry.
3. Water-filled vs oil-filled vs encapsulated
| Feature | Water-filled (wet stator) | Oil-filled | Encapsulated / canned |
|---|---|---|---|
| Filling inside motor | Clean water (often with anti-freeze/lubricant) | Insulating oil | Winding sealed in resin or a steel can |
| Winding wire | Copper with PVC / polyethylene / poly-wrapped water-proof insulation | Enamelled copper wire | Enamelled copper, fully potted |
| Rewindable locally | Yes, easiest | Yes, but oil must be changed and kept clean | Usually no – replace stator |
| Risk if leak | Little – water is the coolant anyway | Oil leak can contaminate water | Moisture creeping into resin |
| Typical use in India | Most V4/V6/V8 agricultural and domestic motors | Older and some low-cost models | Branded premium motors, export |
4. Key parameters a designer/winder checks
| Parameter | Why it matters |
|---|---|
| Rated voltage range (for example 180–240 V for 1-phase, 350–440 V for 3-phase) | Indian rural supply is low and unstable; the winding must survive low-voltage running |
| Number of slots (commonly 18 or 24 in V4/V6) and poles (2-pole, ~2800–2900 rpm) | Decides coil groups, pitch and winding data |
| Turns per coil and wire size | Sets flux and current density; copy original data or recalculate |
| Running and starting winding (1-phase) | Starting winding with capacitor gives the starting torque |
| Capacitor value (µF) and voltage | Wrong value = poor starting or overheating of starting winding |
| Connection (3-phase is usually star) | Star reduces phase voltage on the wet insulation |
| Insulation resistance (IR) | Must be high before installation; falling IR = water entry |
| Thrust capacity | Must match pump stages and head |
| Minimum cooling flow past the motor | Below the maker's minimum flow the motor overheats even at rated load |
In India submersible motors are covered by IS 9283 (Motors for submersible pumpsets, third revision in 2024), and the full pumpset by IS 8034:2018. Openwell submersibles are covered by IS 14220.
5. Rewinding steps (water-filled motor)
- Drain water, open the motor, remove rotor and thrust parts. Note slots, coil pitch, turns, wire size and connection before cutting the old winding.
- Cut and remove the burnt coils; clean slots fully. Check laminations for rubbing marks (rubbing = worn bearings).
- Insert slot insulation (slot liners) of correct length and overhang.
- Wind coils on a former with the correct turns and wire. Water-proof wire is thick, so pull it gently to avoid insulation cuts.
- Insert coils as per pitch (chain or concentric pattern), add separators between phases and slot wedges.
- Make connections (star for 3-phase), joint with proper water-proof sleeving and sealing.
- Tie and shape the overhang so the rotor does not touch it.
- Test: continuity and resistance balance per phase, IR to body, then high-voltage test.
- Assemble, fill with clean water, check free rotation, run no-load and check current in all phases.
6. Common failures – root cause – solution
| Failure | Root cause | Solution |
|---|---|---|
| Winding burnt evenly | Long low-voltage running; overload; dry running after water level drops | Use voltage protection and a dry-run protection starter; select correct stages for head |
| One phase burnt (3-phase) | Single-phasing from a loose contact or blown fuse | Single-phase preventer; tighten starter and cable terminals |
| Low IR / earth leakage | Water entering through cable joint or damaged wire insulation | Proper joint kit; careful pulling of wire during winding; IR test before lowering |
| Starting winding burnt (1-phase) | Weak or wrong capacitor; frequent starts | Correct capacitor value; check relay/centrifugal switch if fitted |
| Motor runs hot even at rated load | Not enough water flow over the motor shell | Fit a flow sleeve; place the motor above the inlet |
| Thrust bearing worn | Sand, up-thrust at low head, wrong pump selection | Sand guard, correct pump curve, keep operating point in range |
7. Videos to watch (16)
| # | Video | Channel | Length | Why watch |
|---|---|---|---|---|
| 1 | How do Submersible Pumps Work? | Sabin Civil Engineering (Lesics) | 3:49 | Clear 3D animation of the pumpset |
| 2 | How Submersible Pumps Lift Water From Deep Borewells | LifeAda | 8:35 | Pump stages, motor and installation |
| 3 | Submersible pump kaise kaam karte hain | JAES Company Hindi | 4:15 | Same concept in Hindi |
| 4 | Kirloskar Brothers Pumps Factory Tour – how a submersible is made | Indian Farmer (Hindi) | 15:25 | Indian factory process |
| 5 | Automated Submersible Pump Motor Stator Manufacturing | NIDE Group | 6:11 | Automated stator line |
| 6 | Submersible Pump Manufacturing Process – Falcon Pump | PUMP dOST | 13:22 | End-to-end manufacturing |
| 7 | Manufacturing Process of Submersible Winding Wire | Manufacturing Hub (India) | 23:46 | How water-proof winding wire is made |
| 8 | 6 HP 24-slot 3-phase Submersible – Full Winding Data (V6) | Technical Kafi (Hindi) | 21:35 | Real winding data and connection |
| 9 | 5 HP 24-slot 3-phase V6 Chain Winding + Star Connection | Technical Kafi (Hindi) | 32:49 | Chain winding method |
| 10 | V8 15 HP 3-phase 24-slot Full Rewinding + Data | Basic Electric BD | 31:43 | Larger V8 motor |
| 11 | 3-phase Submersible Motor Winding with All Diagrams | Hi power electric works | 26:39 | Winding diagrams explained |
| 12 | V4 Single-phase Submersible – Winding Data & Connection | Technical ksp | 35:54 | Running and starting winding data |
| 13 | Single-phase 1 HP Submersible Motor Winding | Hi power electric works | 36:23 | Full 1-phase rewinding |
| 14 | How to Rewind a V-6 Submersible Pump | Musa tech4U | 26:53 | Opening, coil removal, insertion |
| 15 | 10 HP 3-phase Submersible Motor Rewinding | SLV Motor and Electrical (Kannada) | 19:45 | Rewinding in Kannada |
| 16 | Permanent Magnet Technology in Submersible Motors | Franklin Electric EMENA Water | 1:45 | Where submersibles are heading (PM motors) |
8. Sources referred
- IS 8034:2002 Submersible Pumpsets – summary, BIS / National Consumer Helpline
- IS 9283:2024 Line Operated AC Motors for Submersible Pumpsets (Third Revision), BIS
- BIS Product Manual for Submersible Pumpsets as per IS 8034:2018 (routine tests: IR, HV, no-load, locked rotor)
- Submersible motor designs – Ground Water Canada
- Submersible Motor Winding Wire Selection for Water-Filled Applications – Industrial Monitor Direct
- Submersible Pump Motor Troubleshooting: Winding and Insulation Resistance – A.Y. McDonald
Share your experience. Have winding data, a shop-floor photo or a doubt on this topic? Join the MotorMakers India community and help others learn.